Regeneration function protection for island detection,
energy recovery technology for reducing company operating costs
- Regenerative efficiency> 90%, current THD <5%, PF> 0.95
- Stable status of AC voltage during regeneration
- Satisfy the test requirements of VDE-4105-AE (optional)
Security design for risk management
- The hardware protection: overvoltage protection, under voltage protection, overcurrent protection, temperature protection, capacity protection... etc.
- The software protection (optional): battery management system message protection, data logger acquisition data protection, thermostat status protection
- System protection (optional): Insulation monitoring protection, islanding protection
- Independence protection: independent over-voltage measurement, block output immediately if abnormal
Flexible configuration of high-power testing equipment is satisfied
for test requirements of energy storage system and electric vehicle application
- Voltage:1700V/850V, Current:400A/600A, Power:Up to 1.6MW/Up to 2.4MW
- Two voltage and current operating ranges, more flexible in application (specific model only): 200kW/ 850V/ 800A and 200kW/ 1700V/ 400A
▲ VI Operating Range for 17040E (69420E-1700-400)
▲ VI Operating Range for 17040E (69420E-850-600)
- Flexible Integration for Complete Test Solution (optional): Chamber, data recorder, BMS data recording/control, chiller, chamber, vehicle ECU simulator... etc.