Chroma's passive component test solutions provide the instruments, systems, and automated test equipment required for production and reliability testing on various passive components such as inductors, transformers, capacitors, and resistors. They can also be used to test the LCR and insulation resistance parameters. Chroma's electrical safety test solutions encompass measuring instruments such as AC and DC withstand voltage, insulation, ground resistance, and dynamic leakage current required by electronic products and parts. The automated systems meet composite testing of medical equipment. The partial discharge testers detect abnormal discharges to ensure product quality. For various electromagnetic coils, Chroma also provides high-tech layer short test equipment and comprehensive test equipment, which simplifies the complex requirements of the test system.

Quick Menu

LCR-Meter / automatische Transformator Prüfung

RF-LCR-Messgerät Model11090-030
  • CE Mark
  • Rohs 2 Compliant
RF-LCR-Messgerät
Model 11090-030
  • Messparameter: Z, θz, Y, θy, R, X, G, B, Ls, Lp, Cs, Cp, Rs, Rp, D, Q
  • Testfrequenzen: 100 kHz – 300 MHz
  • Messbereich: 100 mΩ – 5 kΩ
  • Messgeschwindigkeit: 0,5/ 0,9/ 2,1/ 3,7 (ms)
  • Messbereich: 100 mΩ – 5 kΩ
HF-LCR-Meter Model11050Series
  • CE Mark
HF-LCR-Meter
Model 11050 Series
  • Prüffrequenz: 75kHz~30MHz/1kHz~10MHz/60Hz~5MHz
  • Grundlegende Genauigkeit: 0,1 %
  • Messzeit: 7 ms
  • Standard-RS-232, Handler, USB-Speicherschnittstelle, optionales GPIB, LAN-Schnittstelle
LCR-Meter Model11021/11021-L
  • CE Mark
LCR-Meter
Model 11021/11021-L
  • Prüffrequenz: 100, 120, 1 k, 10 kHz (11021) / 1 k, 10 k, 40 k, 50 kHz (11021-L)
  • Grundgenauigkeit: 0,1 % (11021) / 0,2 % (11021-L)
  • Messzeit: 75 ms
  • Standard-RS-232-Schnittstelle, optionale GPIB- & Handler-Schnittstelle
LCR-Meter Model11022/11025
  • CE Mark
LCR-Meter
Model 11022/11025
  • Prüffrequenz: 50, 60, 100, 120, 1 k, 10 k, 20 k, 40 k, 50 k, 100 kHz
  • Grundgenauigkeit: 0,1 %
  • Messzeit: 21 ms
  • Standard-RS-232-, GPIB- und Handler-Schnittstelle
AutomatischesTransformator-Prüfgerät Model13350
  • CE Mark
Automatisches Transformator-Prüfgerät
Model 13350
  • Prüffrequenz: 20Hz~200kHz / 20Hz~1MHz
  • Grundgenauigkeit: 0,1 %
  • Optionale Vorrichtungen für unterschiedliche Anwendungen: 20CH-Scaneinheit, 80CH-Scanbox und C.T.-Prüfvorrichtung
  • Standard-RS-232-, USB-Speicher-Schnittstelle, optionale LAN- & USB-H-Schnittstelle
Vorspannungs-Stromquelle Model1320/1320S/1320-10A
  • CE Mark
Vorspannungs-Stromquelle
Model 1320/1320S/1320-10A
  • Frequency Response:
    • 1320/1320S/1320-10A: 20Hz~1MHz
  • Output current:
    • 1320-10A: 0.001A~10.00A
    • 1320/1320S: 0.001A~20.00A
  • Directly controlled by LCR meter 11022/11025/3252/3302 (1320/1320S/1320-10A)
  • Standard GPIB and Handler I/F
Bias-Strom-Testsystem Model11300
  • CE Mark
Bias-Strom-Testsystem
Model 11300
  • Frequenzbereich: 20 Hz – 1 MHz
  • Ausgangsstrom: bis 300,0 A durch 20,00-A-Module
  • Ausgangsstromgenauigkeit: 3 %
  • Software auf Windows-Basis für Kurvenanalyse

Isolationsprüfgerät

Batteriezellen-Isolationsprüfer Model11210
  • UL-Canada
Batteriezellen-Isolationsprüfer
Model 11210
  • Prüfspannung: Bis max. 1 KV(dc)
  • Ladestrom: 50 mA max.
  • Breiter Messbereich für Verluststrom (LC) (1pA ~ 20mA)
  • Automatischer Test in folgender Reihenfolge: Aufladen-Verweilen-Messen-Entladen
Kondensator-Verluststrom/IR-Meter Model11200
  • CE Mark
Kondensator-Verluststrom/IR-Meter
Model 11200
  • Gleichstromspannung: 1,0 V – 650 V / 800 V
  • Ladestrom: 0,5 mA – 500 mA
  • Verluststrommessung: 0,001 uA – 20,00 mA
  • Standard-RS-232-Schnittstelle, optionale GPIB- & Handler-Schnittstelle

Passive Bauteile ATS

Kondensator-Prüfsystem Model1820
Kondensator-Prüfsystem
Model 1820
  • Hochfrequenter Sinusstrom: 1 kHz - 20 kHz, 10 kHz - 200 kHz
  • DC-Vorspannung: Max. 5000 V
  • Dauerfestigkeits- und Temperaturanstiegsprüfung für Kondensatoren
  • Prüfung der Kondensatorfestigkeit (Frequenzdurchlauf)
  • Unterstützung bei der Softwaresteuerung
  • Kundenspezifisches Prüfmodul1820